![]() | Creative Labs
Khuda Khurd, Ambala, Haryana GST No. 06BABPM7520F1Z0 |
Price on Request: Get Latest Price
The set up consist of three vertical column packed with activated Charcoal. Columns are operated individually. Liquid feed with dye is fed to the individual column from the bottom and samples are collected from the top at regular interval of time. Rotameter is provided to measure the flow rate. Pump with a feed tank is provided for fluid flow.Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
DESCRIPTION:-Price on Request: Get Latest Price
DESCRIPTION:-Price on Request: Get Latest Price
The column is made of Stainless Steel with seven plates for mounting the bubble caps. Each plate is provided with one bubble cap. An electrically heated reboiler is installed at the bottom of the column. The bottom product is collected in the tank. The vapours form the top of column are condensed in the shell and tube type condenser by cooling water supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation provided for pressure & temp. measurement wherever necessary.Price on Request: Get Latest Price
Computer Controlled - Bubble Cap Distillation Column (With Data Logging Facility)Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
The column is made of Stainless Steel material packed with Borosilicate Glass rasching rings. An electrically heated reboiler is installed at the bottom of the column. The bottom product is collected in the tank. The vapours form the top of column are condensed in the shell and tube type condenser by circulating cooling water, supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is provided for pressure & temp. measurement wherever necessary. The present set-up has a facility to interface the system with computer which enables to log the experimental data using computer. The educational software and data-logging package has been developed for unit. The softwarePrice on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
Computer Controlled - Simple Steam Distillation Setup (With Data Logging Facility)Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
Computer Controlled - Simple Batch Distillation Setup (With Data Logging Facility)Price on Request: Get Latest Price
The set up consists of a column fitted with perforated plates. Liquid is fed at the top of the column through distributor. The solute gas and air are measured separately, mixed in a mixing chamber and then passed through the perforated plates vertically upward and absorbed in liquid. All the flow rates can be independently varied to simulate different conditions. Liquid Sample can be taken out from the bottom of the column for analysis.Price on Request: Get Latest Price
The set up consists of a glass column packed with Rasching rings. Liquid is fed at the top of the column through distributor. The solute gas and air are measured separately, mixed in a mixing chamber and then passed through the packed column vertically upward and absorbed in liquid. All the flow rates can be independently varied to simulate different conditions. Liquid sample can be taken out from the sampling point at the bottom of the column for analysis.Price on Request: Get Latest Price
The set up consists of a glass column. Alkaline liquid is fed at the top of the column along the walls to create a laminar liquid flow along the walls of a wetted wall column. Flow rates of Air and Co2, are measured separately, mixed in a mixing chamber and then passed through the column vertically upward and absorbed in liquid film around the wall. All the flow rates can be independently varied to simulate different conditions. Liquid Sample can be taken out from the sampling point at the bottom of the column for analysis.Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
DESCRIPTION :Price on Request: Get Latest Price
Natural Draft Tray Dryer is a dryer in which moisture removal takes place by heat under natural condition. The set-up consists of an insulated Stainless Steel chamber fitted with heater. Inside the chamber a tray is attached directly to an electronic weighing balance, which is fitted on the bottom, outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Temperature controller fitted in the set-up maintains the required temperature in the chamber.Price on Request: Get Latest Price
DESCRIPTION :Price on Request: Get Latest Price
This is a dryer in which moisture removal takes place by means of forced draft action created by hot air. The set-up consists of an insulated double wall chamber. Inside the chamber a tray is attached directly to a electronic weighing balance, which is fitted on the bottom, outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Air from a blower passes through a heating chamber and is used as drying agent. Arrangement is done to vary the airflow rate.Price on Request: Get Latest Price
DESCRIPTION :Price on Request: Get Latest Price
Automatic Grade | Automatic |
Price on Request: Get Latest Price
This is a dryer in which moisture removal takes place by fluidization of solids particles by hot air. The set-up fitted with a specially designed, vertical Glass Column. The lower portion of the column is filled with fluidizing material. The material is supported on the screen mesh held between two flanges. Air from a compressor is heated in the heater box and passed through the column. Flow control and by-pass valve are fitted to regulate the airflow. At the top outlet of column a cyclone is provided to collect any solid particles taken out by the air stream.Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
Computer Controlled - Vapour-liquid Equilibrium Set-up (With Data Logging Facility)Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
Experimental water-cooling tower is a forced draft counter flow type cooling tower specially designed for the Engineering students to provide them insight about actual working of tower. In this system, air from a fan enters at the bottom of the tower and after passing through the mesh packing, discharges into the atmosphere via a duct. Airflow is controlled by a butterfly valve on the blower's delivery line. Water is evenly distributed over the packing by nozzles at top of the tower. Water flow and temperatures can be measured and controlled with suitable instrumentation provided. A water tank at the bottom fitted with level gauge enables to show the exact evaporation loss. Front side acrylic sheet provides actual visualization of cooling tower operation. Air and water flow rates as well as inlet water temperatures can be varied to have different sets of readings.Price on Request: Get Latest Price
DESCRIPTIONPrice on Request: Get Latest Price
Rotary dryer is a unit in which drying is done by forced draft action created by hot air. The set-up consists of a long revolving cylindrical shell slightly inclined towards the outlet. The shell is fitted with two brackets for support. Air from a blower passes through a heating chamber serves the purpose of drying agent. An arrangement for rotating the dryer shell at low RPM is provided by means of an electrical motor and a reduction gearbox.Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
DESCRIPTION:Price on Request: Get Latest Price
Experimental water-cooling tower is a forced draft counter flow type cooling tower specially designed for the Engineering students to provide them insight about actual working of tower. In this system, air from a fan enters at the bottom of the tower and after passing through the mesh packing, discharges into the atmosphere via a duct. Airflow is controlled by a butterfly valve on the blower's delivery line. Water is evenly distributed over the packing by nozzles at top of the tower. Water flow and temperatures can be measured and controlled with suitable instrumentation provided. A water tank at the bottom fitted with level gauge enables to show the exact evaporation loss. Front side acrylic sheet provides actual visualization of cooling tower operation. Air and water flow rates as well as inlet water temperatures can be varied to have different sets of readings.