Creative Labs
Creative Labs
Khuda Khurd, Ambala, Haryana
GST No. 06BABPM7520F1Z0
Send E-mail
Call 0804603471466% Response Rate
Home  » Products » 

Mass Transfer Lab Apparatus


Our domain expertise has enabled us to come up with a remarkable gamut of Mass Transfer Lab Apparatus. These are designed with utmost precision by our experts following the set industry standards and quality norms. Our raw material for the product is sourced from some of the most reliable vendors in this industry. We accept bulk orders for the offered range of products and ensure their delivery within the postulated time. These are widely applauded for their features like easy installation, low maintenance, high performance and longer functional life.

 



REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

We are instrumental in offering superior quality Mass Transfer Lab Equipment to the esteemed customers, as per their specific demands. These mass transfer labs are designed in such a manner that our clients' exact requirements get fulfilled by us. In addition to this, we have gained expertise in offering customized products to the clients.

 

Application Area Of Product:

  • Solid-Liquid Extraction (Packed Bed Type)

  • Absorption in Wetted Wall Column

  • Packed Distillation Column

  • Bubble Cap Distillation Column

  • SIMPLE STEAM Distillation Set-up

  • Swenson Walker Crystallizer

  • Absorption in Packed Bed

  • Liquid Liquid Extraction in Packed Bed

  • Sieve Plate Distillation Column

  • Spray Extraction Column

  • Absorption in Sieve Plate Column

  • Fluidized Bed Dryer

  • Vapor in Air Diffusion Apparatus

  • Forced Draft Tray Dryer

  • Fixed Bed Absorption with Regeneration

  • Solid in Air Diffusion Apparatus

  • Natural Draft Tray Dryer

  • York Scheibel Extraction Column

  • Liquid in Liquid Diffusion Apparatus

  • Rotary Dryer

  • Batch Crystallizer

  • Mass Transfer with/without Chemical Reaction

  • (Solid-Liquid System)

  • Solid-Liquid Extraction (Bonnoto type)

  • Vapor-Liquid Equilibrium Set-Up

  • Wetted Wall Column, Humidification & De-Humidification Study

  • Experimental Water Cooling Tower

  • Ion Exchange


Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

The setup is designed to demonstrate principles of extraction and mass transfer operation in a YORK SCHEIBEL'S column.

The set up consists of a glass column, feed tanks, air regulator with pressure gauge, receiving tanks and piping. Rotameter are provided for flow measurement.

The glass column is divided into multiple stages; each stage consists of a woven wire mesh (calming) section and a mechanical agitation section. The agitator speed can be varied by drive. The presence of alternatively agitating and calming sections yield higher extraction efficiency than conventional packed column

Experiments

  • Determination of overall height of a transfer unit and overall volumetric mass transfer coefficient

Features

  • Stainless Steel tanks and wetted parts
  • Special arrangement for changing height of interface zone
  • Continuous operation
  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Electric supply Provide 230 /- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor
  • Chemicals for trial as per your choice
  • Compressed Air supply: Clean, oil and moisture free air, pressure 2 Bar.
  • Water Supply & Drain as required

Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

The equipment consists of jacketed pressure vessel for distillation. Steam from a steam generator can either be allowed to enter 'in the outer jacket or in the vessel. The vapors form the top of the vessel are condensed in the shell and tube type condenser by circulating cooling water supplied by laboratory overhead tank.

The condensate is colleted in a separating chamber. The set-up is fitted with steam trap control valves pressure gauge, temperature sensors and other instrumentations required

Experiments

  • To study the Packed Distillation Column

Features

  • Stainless Steel tanks and wetted parts
  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Water Supply 2 LPM at 5 m head
  • Drain
  • Electricity Supply: 1Phase, 220 V AC, 6.5 kW
  • Required Chemicals
  • Refractrometer for analysis

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

Product Details:
Design TypeStandard

The setup is designed to demonstrate principles of distillation in a Sieve Plate Column.

The column is made of Stainless Steel material with seven sieve trays. An electrically heated re-boiler is installed at the bottom of the column. The bottom product is collected in the tank. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp. Measurement wherever is necessary

Experiments

  • To study the Sieve Plate Distillation Column

Features

  • Stainless Steel tanks and wetted parts
  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Water Supply 2 LPM at 5 m head
  • Drain
  • Electricity Supply: 1Phase, 220 V AC, 6.5 kW
  • Required Chemicals
  • Refractrometer for analysis

Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

The setup is designed to demonstrate principles of distillation in a Packed Column.

The column is made of Stainless Steel material packed with Borosilicate Glass rasching rings. An electrically heated re-boiler is installed at the bottom of the column. The bottom product is collected in the tank. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water and it is supplied by laboratory overhead tank.

The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp measurement wherever is necessary

Experiments

  • To study the Packed Distillation Column

Features

  • Stainless Steel tanks and wetted parts
  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Water Supply 2 LPM at 5 m head
  • Drain
  • Electricity Supply: 1Phase, 220 V AC, 6.5 kW
  • Required Chemicals
  • Refractrometer for analysis




Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

The set up consists of glass column packed with rasching rings, feed tank, CO2 cylinder with regulator, air regulator with pressure gauge, rotameter, receiving tray and piping. Metered quantity of fluid is distributed over the packing while metered gas and airflow is passed through the bed vertically upwards.

The gas air mixture is absorbed in the liquid. All the flow rates can be independently varied to simulate different conditions and by measuring the concentration of gas absorbed in the liquid the overall volumetric mass transfer coefficients can be calculated

Experiments

  • Determination of overall gas transfer coefficient

Features

  • Continuous operation
  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up
  • Stainless Steel tanks and wetted parts

Utilities Required

  • Electric supplyProvide 230 /- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor
  • Chemicals for trial Sodium Hydroxide (NaOH)- 40gm, Hydrochloric Acid (HCl) 1N- 500ml, Barium Chloride (BaCl2) - 100gm, Phenolphthalein indicator-10ml, Methyl orange indicator- 10ml (Or as per your choice)
  • Compressed Air supply using a compressor: Clean, oil and moisture free air, pressure 5 Bar.
  • Water Supply & Drain as required

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

Diffusivity of the vapors is determined by WINKELMANN method in which liquid is allowed to evaporate in a graduated vertical glass tube over the top of which a stream of air is passed.

The setup contains all necessary accessories to determine the diffusion coefficient of vapors (liquid) in air phase. The diffusion vessel is of high quality Borosilicate Glass with a T type diffusion tube engraved in mm scale for level readings. The vessel is mounted over a Magnetic Stirrer cum hot plate of Superior quality provided with controls for vary the temperature and RPM to calculate the rate of diffusion at different temperature. The Air Flow stream is generated using mini-air pump

Experiments

  • Determination diffusion coefficient for liquid / vapor in air system

Features

  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Electric supplyProvide 230 /- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor
  • Chemicals for trial Acetone / CCl4 (Or as per your choice)

Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

With firm commitment to quality, we are engaged in offering excellent quality, Solid Liquid Extraction (Packed Bed Type) . These are designed under the strict command of our quality analyzers keeping in mind the industry guidelines. Post production, these products are stringently tested on varied grounds, to ensure their compliance with international quality standards.

 

Features:

  • Durability

  • High tensile strength

  • Resistance to corrosion


Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

We are offering superior quality Adsorption in Packed Bed to the esteemed customers, as per their specific demands. These are designed under the strict command of our quality analyzers keeping in mind the industry guidelines. We make sure to timely deliver the ordered products at the customers' end, via our wide distribution network.

Utilities Required:

  • Water Supply & Drain
  • Electricity Supply: I Phase, 220VAC, 1.5kW
  • Instruments, Laboratory Glassware and Chemicals required for analysis as per the system adopted

Specifications:

Product
Adsorption Setup
Reactor Column
Material Borosil Glass, different diameter with different height of packing (3 Nos.)
Feed Tank
Material Stainless Steel, Capacity 20 Ltrs., feed lines, drain valve etc. (1Nos.)
Receiving Tank
Material Stainless Steel, Capacity 20 Ltrs (1Nos.)
Feed Circulation
By pump, Magnetic drive made of Polypropylene (1Nos.)
Flow Measurement
Rota-meter 1 Nos. (for feed)
Feed Piping
PVC / SS size
Stop Watch
Electronic
Control Panel
On off switch, Mains Indicator etc.
The setup is painted with good quality paints & mounted on a strong support.

Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

The setup is designed to demonstrate principles of spray extraction and mass transfer operation in a column.

The set up consists of a glass column, feed tanks, air regulator with pressure gauge, receiving trays and piping. Rotameter are provided for flow measurement

Experiments

  • Determination of overall height of a transfer unit and overall volumetric mass transfer coefficient

Features

  • Stainless Steel tanks and wetted parts
  • Special arrangement for changing height of interface zone
  • Continuous operation
  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Electric supply Provide 230 /- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor
  • Chemicals for trial as per your choice
  • Compressed Air supply: Clean, oil and moisture free air, pressure 2 Bar.
  • Water Supply & Drain as required

 


Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

The setup is designed to demonstrate principles of distillation in a Bubble Cap column.

The column is made of Stainless Steel with seven plates for mounting the bubble caps. Each plate is provided with one bubble cap. An electrically heated re-boiler is installed at the bottom of the column. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water supplied by laboratory overhead tank.

The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp measurement wherever is necessary

Experiments

  • To study the Bubble Cap Distillation Column

Features

  • Stainless Steel tanks and wetted parts
  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Water Supply 2 LPM at 5 m head
  • Drain
  • Electricity Supply: 1Phase, 220 V AC, 6.5 kW
  • Required Chemicals
  • Refractrometer for analysis

Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

The set-up is designed to demonstrate and stimulate the phenomena of crystallization. This operation involves both heat and mass transfer. Crystallization is the formation of solid particles within a homogeneous phase. Its wide use has a two-fold basis; a crystal formed from an impure solution is itself pure.

The setup consists of an open, jacketed and conical bottom vessel fitted with a low RPM agitator and a heater. Arrangement for Cooling water circulation and flow measurement in jacket is made by using storage type water tank, a pump and a rotameter.

The feed/mother liquor is prepared in the crystallizer vessel itself using heater and stirrer. The hot super saturation solution in the crystallizer is then cooled by circulation of cooling water and crystals are formed. Necessary instrumentation is done for temp measurement

Experiments

  • To study the performance of a Batch Crystallizer

Features

  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

Electric supplyProvide 230 /- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for

Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

Product Details:
Automatic GradeAutomatic

The set-up is designed to demonstrate and stimulate the moisture removal by heat under natural draft action created by hot air stream.

The set-up consists of an insulated double wall chamber. Inside the chamber a tray is attached directly to an electronic weighing balance, which is fitted on top outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Air works as the drying agent by natural action removes the moisture from the tray by passing towards the top openings. A digital temperature controller is used to control and measure the temperature of air stream l

Experiments

  • Determination of rate of drying of wet sawdust under different conditions of temperature

Features

  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with switch for heater
  • Material Saw dust @ 1Kg.
  • Support table Size: 500Wx500Dx750H in mm

 


Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

Product Details:
Automatic GradeAutomatic

The set-up is designed to demonstrate and stimulate the moisture removal by heat under forced draft action created by hot air stream.

The set-up consists of an insulated double wall chamber. Inside the chamber a tray is attached directly to an electronic weighing balance, which is fitted on top outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Air from blower passes through heating chamber to produce hot air works as the drying agent entered from one side of the chamber and leave the chamber from other side removes the moisture from the tray. An arrangement is made to vary and measure the airflow rate. A digital temperature controller is used to control and measure the temperature of air stream.

>Experiments

  • Determination of rate of drying of wet sawdust under different conditions of temperature and air flow

Features

  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Electric supply Provide 230 /- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with switch for heater
  • Material Saw dust @ 1Kg.
  • Anemometer Air flow measurement

Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

Product Details:
Automatic GradeAutomatic

The set-up is designed to demonstrate and stimulate the moisture removal by heat under forced draft action created by hot air stream and fluidization property of solid to dry.

The set-up consists of a specially designed, vertical Column. The lower conical portion of the column is filled with moist solids. The material is supported on the screen mesh held between two flanges. Air from blower passes through heating chamber to produce hot air works as the drying agent entered from lower side of the column and leave the column from top outlet removes the moisture of solids. At the top outlet of column a cyclone is provided to collect the solid particles taken out by the air stream. An arrangement is made to vary and measure the airflow rate. A digital temperature controller is used to control and measure the temperature of air stream

Experiments

  • To study the fluidized bed drying

Features

  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for weighing scale, 15A, three pin socket with switch for heater
  • MaterialSaw dust @ 1Kg. Granular and free flowing solid of size I - 2 mm
  • Anemometer Air flow measurement

 


Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

Product Details:
Automatic GradeAutomatic

We are leading manufacturer and exporter of a wide range of Fluidized Bed Dryer. The Salt is fluidized, each particle meets the hot air, discharges moisture, gets dry and at the same time travels forward without any mechanical push. We have proven-technology for designing dryers of any capacity. In this state, the solids behave like a free flowing boiling liquid. Clients can avail this products as per there requirements.

Scope of Experimentations:
  • To study fluidization characteristics
  • To study relationship between velocity of fluid and pressure drop per unit length

Utilities Required:
  • Electricity : 500 watts, 220 V, 1 Phase
  • Floor Area : 0.75 m x 0.75 m

Technical Details:
  • Column : Material Borosilicate Glass
  • Packing : Glass Beads
  • Water tank : Material Stainless Steel, Capacity 30 Ltrs
  • Water Circulation : FHP Pump, Crompton/Sharp make
  • Flow Measurement : Rotameter for water
  • Pr. Drop Measurement : Manometer
  • The whole set-up is well designed and arranged in a good quality painted structure

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

This setup is designed to study the performance characteristics of solvent extraction of a particular component from a packed bed of solid material. The apparatus allows study of such systems as water / inorganic salts, water/sugar bed, methylene chloride / vegetable oil etc.

The set up consists of a glass column, feed tank, receiving tanks and piping. Rotameter are provided for flow measurement. The glass column is fitted with SS mesh to support the solid material.

The solvent is introduced near the bottom of the column and it flow upward counter currently to the solids. A pump supplies the solvent and flow rate is monitored by means of a Rotameter. Solvent feed tank is kept in a bath fitted with heater. A digital temperature controller is used to control and measure the temperature of feed

Experiments

  • To study the effect of various system parameters like, solvent temperature, solvent rate and particle on the % recovery of oil from solid

Features

  • Stainless Steel tanks and wetted parts
  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Electricity Supply: 1 Phase, 220 V AC, 1.5kW.
  • Solvent: 30ltrs
  • Solid: 10kg.
  • Table for setup support



Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

The setup is designed to demonstrate principles of extraction in a Bonnotto type extraction column. It consists of a SS column, feed tank with heating arrangement, receiving tanks and piping. Rotameter is provided for flow measurement.

The column is divided into multiple stages; each stage consists of a plate and a mechanical agitation section. The circular plates are arranged one above the other in opposite radial opening, yield higher extraction efficiency than conventional packed column.

The solids are introduced at the top through a hopper spread over the top plate and pushed to slot to fall to the next plate below and so on to the bottom of the column. The solvent is introduced near the bottom of the column and it flow upward counter-currently to the solids. A pump supplies the solvent and flow rate is monitored by means of a Rotameter. At the bottom of column a screw conveyor arrangement is done to remove the extracted solids driven by means of an electric motor. Solvent feed tank is kept in a bath fitted with heater. A digital temperature controller is used to control and measure the temperature of feed

Experiments

  • To determine the efficiency of a continuous counter-current Solid-Liquid Extraction

Features

  • Stainless Steel tanks and wetted parts
  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Electric supply 1Phase, 220 V AC, 3 kW
  • Chemicals for trial Solvent: 50ltrs Solid: 30kg as per your choice of system adopted as per your choice
  • Water Supply & Drain as required




Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

The setup is designed to demonstrate principles of liquid-liquid extraction and mass transfer operation in a packed column.

The set up consists of a glass column, packing, feed tanks, air regulator with pressure gauge, receiving tanks and piping. Rotameter are provided for flow measurement

Experiments

  • Determination of overall height of a transfer unit and overall volumetric mass transfer coefficient

Features

  • Stainless Steel tanks and wetted parts
  • Special arrangement for changing height of interface zone
  • Continuous operation
  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Electric supply Provide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor
  • Chemicals for trial as per your choice
  • Compressed Air supply: Clean, oil and moisture free air, pressure 2 Bar.
  • Water Supply & Drain as required

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

The set up consists of glass column, feed tank, CO2 cylinder with regulator, air regulator with pressure gauge, Rotameter, receiving tray and piping. Metered quantity of fluid is distributed along with the walls of column from the top while metered gas and airflow is passed through the bed vertically upwards.

The gas air mixture is absorbed in the liquid. All the flow rates can be independently varied to simulate different conditions and by measuring the concentration of gas absorbed in the liquid the overall volumetric mass transfer coefficients can be calculated.

Experiments

  • Determination of overall gas transfer coefficient

Features

  • Continuous operation
  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up
  • Stainless Steel tanks and wetted parts

Utilities Required

  • Electric supplyProvide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Compressor
  • Chemicals for trial Sodium Hydroxide (NaOH)- 40gm, Hydrochloric Acid (HCl) 1N- 500ml, Barium Chloride (BaCl2) - 100gm, Phenolphthalein indicator-10ml, Methyl orange indicator- 10ml (Or as per your choice)
  • Compressed Air supply using a compressor: Clean, oil and moisture free air, pressure 5 Bar.
  • Water Supply & Drain as required

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

The set up consists of glass column, packing material, air rotameter and piping. Metered quantity of airflow is passed through the packed bed vertically upwards.

The flow rate can be independently varied to simulate different conditions using rotameter. Naphthalene balls of known weight and diameter are used to form the packed bed for the calculation of mass transfer co-efficient of vaporization in air

Experiments

  • To calculate the mass transfer co-efficient of vaporization of naphthalene in air using a packed bed of spherical particles of naphthalene

Features

  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Electric supplyProvide 230 +/- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Mini Air Compressor
  • Chemicals for trial Naphthalene Balls (Or as per your choice)
  • Air supply: Clean, oil and moisture free air, pressure 2 Bar
  • Weighing Balance 0.1gm resolution

Yes! I am Interested


Ask for Price

Price on Request: Get Latest Price

The setup contains all necessary accessories to determine the diffusion coefficient of components in the liquid phase.

The discussion cell is a well designed one to avoid any error during equimolal counter current diffusion between liquids of different concentration on each side of the cell. The diffusion vessel is of high quality Borosilicate Glass with a porous cell made up of ceramic. The Concentration of Solution is precisely measured with a precision Conductivity meter provided along with the setup.

The vessel is mounted over a Magnetic Stirrer cum hot plate of Superior quality provided with controls for vary the temperature and RPM to calculate the rate of diffusion at different temperature and mixing level

Experiments

  • Determination diffusion coefficient
  • To study the effect of temperature on diffusion co-efficient

Features

  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Electric supplyProvide 230 /- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch for Hot plate and conductivity meter
  • Chemicals for trial as per your choice

Yes! I am Interested


REQUEST CALLBACK
Ask for Price

Price on Request: Get Latest Price

The set-up is designed to demonstrate and stimulate the phenomena of crystallization. Swenson Walker crystallizer is a continuous type crystallizer. This operation involves both heat and mass transfer. Crystallization is the formation of solid particles within a homogeneous phase. Its wide use has a two-fold basis; a crystal formed from an impure solution is itself pure.

The setup consists of a top open jacketed round bottom trough. A ribbon mixer is provided in crystallizer trough, which rotates at low rpm for agitation of saturated solution. The saturated solution is prepared in a tank fitted with heater and a stirrer. This hot saturated solution is fed at one end of the crystallizer and flows slowly towards the other end while being cooled and is allowed to flow back in hot feed tank making the process continuous. The crystals sediments at the bottom of the trough, and can be washed out at the end of process. Arrangement for Cooling water circulation and flow measurement in jacket is made by using storage type water tank, a pump and a rotameter. Necessary instrumentation is done for temp measurement

Experiments

  • To study the performance of a Swanson Walker Crystallizer
  • To determine the crystal yield and the efficiency of crystallizer

Features

  • Superb Painted structure
  • Simple to operate & maintain
  • Compact & stand alone set up

Utilities Required

  • Chemicals commercial grade material as per choice

Yes! I am Interested


 






Corporate Brochure




 

 

Send SMS
Sagar Sharma  (Managing Director)
Creative Labs
,12,Jagadhari Road,,chota khudda Industrial Estate
Khuda Khurd, Ambala - 133001 , Haryana , India
Send E-mail
Share Us:
X