Our domain expertise has enabled us to come up with a remarkable gamut of Mass Transfer Lab Apparatus. These are designed with utmost precision by our experts following the set industry standards and quality norms. Our raw material for the product is sourced from some of the most reliable vendors in this industry. We accept bulk orders for the offered range of products and ensure their delivery within the postulated time. These are widely applauded for their features like easy installation, low maintenance, high performance and longer functional life.
Price on Request: Get Latest Price
The setup is designed to demonstrate principles of extraction and mass transfer operation in a YORK SCHEIBEL'S column.
The set up consists of a glass column, feed tanks, air regulator with pressure gauge, receiving tanks and piping. Rotameter are provided for flow measurement.
The glass column is divided into multiple stages; each stage consists of a woven wire mesh (calming) section and a mechanical agitation section. The agitator speed can be varied by drive. The presence of alternatively agitating and calming sections yield higher extraction efficiency than conventional packed column
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
The equipment consists of jacketed pressure vessel for distillation. Steam from a steam generator can either be allowed to enter 'in the outer jacket or in the vessel. The vapors form the top of the vessel are condensed in the shell and tube type condenser by circulating cooling water supplied by laboratory overhead tank.
The condensate is colleted in a separating chamber. The set-up is fitted with steam trap control valves pressure gauge, temperature sensors and other instrumentations required
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
Design Type | Standard |
The setup is designed to demonstrate principles of distillation in a Sieve Plate Column.
The column is made of Stainless Steel material with seven sieve trays. An electrically heated re-boiler is installed at the bottom of the column. The bottom product is collected in the tank. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water supplied by laboratory overhead tank. The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp. Measurement wherever is necessary
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
The setup is designed to demonstrate principles of distillation in a Packed Column.
The column is made of Stainless Steel material packed with Borosilicate Glass rasching rings. An electrically heated re-boiler is installed at the bottom of the column. The bottom product is collected in the tank. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water and it is supplied by laboratory overhead tank.
The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp measurement wherever is necessary
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
The set up consists of glass column packed with rasching rings, feed tank, CO2 cylinder with regulator, air regulator with pressure gauge, rotameter, receiving tray and piping. Metered quantity of fluid is distributed over the packing while metered gas and airflow is passed through the bed vertically upwards.
The gas air mixture is absorbed in the liquid. All the flow rates can be independently varied to simulate different conditions and by measuring the concentration of gas absorbed in the liquid the overall volumetric mass transfer coefficients can be calculated
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
Diffusivity of the vapors is determined by WINKELMANN method in which liquid is allowed to evaporate in a graduated vertical glass tube over the top of which a stream of air is passed.
The setup contains all necessary accessories to determine the diffusion coefficient of vapors (liquid) in air phase. The diffusion vessel is of high quality Borosilicate Glass with a T type diffusion tube engraved in mm scale for level readings. The vessel is mounted over a Magnetic Stirrer cum hot plate of Superior quality provided with controls for vary the temperature and RPM to calculate the rate of diffusion at different temperature. The Air Flow stream is generated using mini-air pump
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
With firm commitment to quality, we are engaged in offering excellent quality, Solid Liquid Extraction (Packed Bed Type) . These are designed under the strict command of our quality analyzers keeping in mind the industry guidelines. Post production, these products are stringently tested on varied grounds, to ensure their compliance with international quality standards.
Features:
Durability
High tensile strength
Resistance to corrosion
Price on Request: Get Latest Price
We are instrumental in offering superior quality Mass Transfer Lab Equipment to the esteemed customers, as per their specific demands. These mass transfer labs are designed in such a manner that our clients' exact requirements get fulfilled by us. In addition to this, we have gained expertise in offering customized products to the clients.
Application Area Of Product:
Solid-Liquid Extraction (Packed Bed Type)
Absorption in Wetted Wall Column
Packed Distillation Column
Bubble Cap Distillation Column
SIMPLE STEAM Distillation Set-up
Swenson Walker Crystallizer
Absorption in Packed Bed
Liquid Liquid Extraction in Packed Bed
Sieve Plate Distillation Column
Spray Extraction Column
Absorption in Sieve Plate Column
Fluidized Bed Dryer
Vapor in Air Diffusion Apparatus
Forced Draft Tray Dryer
Fixed Bed Absorption with Regeneration
Solid in Air Diffusion Apparatus
Natural Draft Tray Dryer
York Scheibel Extraction Column
Liquid in Liquid Diffusion Apparatus
Rotary Dryer
Batch Crystallizer
Mass Transfer with/without Chemical Reaction
(Solid-Liquid System)
Solid-Liquid Extraction (Bonnoto type)
Vapor-Liquid Equilibrium Set-Up
Wetted Wall Column, Humidification & De-Humidification Study
Experimental Water Cooling Tower
Ion Exchange
Price on Request: Get Latest Price
We are offering superior quality Adsorption in Packed Bed to the esteemed customers, as per their specific demands. These are designed under the strict command of our quality analyzers keeping in mind the industry guidelines. We make sure to timely deliver the ordered products at the customers' end, via our wide distribution network.Product | Adsorption Setup |
Reactor Column | Material Borosil Glass, different diameter with different height of packing (3 Nos.) |
Feed Tank | Material Stainless Steel, Capacity 20 Ltrs., feed lines, drain valve etc. (1Nos.) |
Receiving Tank | Material Stainless Steel, Capacity 20 Ltrs (1Nos.) |
Feed Circulation | By pump, Magnetic drive made of Polypropylene (1Nos.) |
Flow Measurement | Rota-meter 1 Nos. (for feed) |
Feed Piping | PVC / SS size |
Stop Watch | Electronic |
Control Panel | On off switch, Mains Indicator etc. |
The setup is painted with good quality paints & mounted on a strong support. |
Price on Request: Get Latest Price
The setup is designed to demonstrate principles of spray extraction and mass transfer operation in a column.
The set up consists of a glass column, feed tanks, air regulator with pressure gauge, receiving trays and piping. Rotameter are provided for flow measurement
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
The setup is designed to demonstrate principles of distillation in a Bubble Cap column.
The column is made of Stainless Steel with seven plates for mounting the bubble caps. Each plate is provided with one bubble cap. An electrically heated re-boiler is installed at the bottom of the column. The vapors form the top of column are condensed in the shell and tube type condenser by circulating cooling water supplied by laboratory overhead tank.
The condensate is divided into reflux and distillate by automatic reflux divider and R/D Ratio can be varied. Reflux is fed back to the column and distillate is received in a receiving tank. The complete column is insulated for minimizing the heat loss. Instrumentation is done for pressure & temp measurement wherever is necessary
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
The set-up is designed to demonstrate and stimulate the phenomena of crystallization. This operation involves both heat and mass transfer. Crystallization is the formation of solid particles within a homogeneous phase. Its wide use has a two-fold basis; a crystal formed from an impure solution is itself pure.
The setup consists of an open, jacketed and conical bottom vessel fitted with a low RPM agitator and a heater. Arrangement for Cooling water circulation and flow measurement in jacket is made by using storage type water tank, a pump and a rotameter.
The feed/mother liquor is prepared in the crystallizer vessel itself using heater and stirrer. The hot super saturation solution in the crystallizer is then cooled by circulation of cooling water and crystals are formed. Necessary instrumentation is done for temp measurement
Experiments
Features
Utilities Required
Electric supplyProvide 230 /- 10 VAC, 50 Hz, single phase electric supply with proper earthing. 5A, three pin socket with switch forPrice on Request: Get Latest Price
Automatic Grade | Automatic |
The set-up is designed to demonstrate and stimulate the moisture removal by heat under natural draft action created by hot air stream.
The set-up consists of an insulated double wall chamber. Inside the chamber a tray is attached directly to an electronic weighing balance, which is fitted on top outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Air works as the drying agent by natural action removes the moisture from the tray by passing towards the top openings. A digital temperature controller is used to control and measure the temperature of air stream l
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
Automatic Grade | Automatic |
The set-up is designed to demonstrate and stimulate the moisture removal by heat under forced draft action created by hot air stream.
The set-up consists of an insulated double wall chamber. Inside the chamber a tray is attached directly to an electronic weighing balance, which is fitted on top outside the chamber. Material for drying is placed in the tray and regular loss of weight is monitored. Air from blower passes through heating chamber to produce hot air works as the drying agent entered from one side of the chamber and leave the chamber from other side removes the moisture from the tray. An arrangement is made to vary and measure the airflow rate. A digital temperature controller is used to control and measure the temperature of air stream.
>Experiments
Features
Utilities Required
Price on Request: Get Latest Price
Automatic Grade | Automatic |
The set-up is designed to demonstrate and stimulate the moisture removal by heat under forced draft action created by hot air stream and fluidization property of solid to dry.
The set-up consists of a specially designed, vertical Column. The lower conical portion of the column is filled with moist solids. The material is supported on the screen mesh held between two flanges. Air from blower passes through heating chamber to produce hot air works as the drying agent entered from lower side of the column and leave the column from top outlet removes the moisture of solids. At the top outlet of column a cyclone is provided to collect the solid particles taken out by the air stream. An arrangement is made to vary and measure the airflow rate. A digital temperature controller is used to control and measure the temperature of air stream
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
Automatic Grade | Automatic |
Price on Request: Get Latest Price
This setup is designed to study the performance characteristics of solvent extraction of a particular component from a packed bed of solid material. The apparatus allows study of such systems as water / inorganic salts, water/sugar bed, methylene chloride / vegetable oil etc.
The set up consists of a glass column, feed tank, receiving tanks and piping. Rotameter are provided for flow measurement. The glass column is fitted with SS mesh to support the solid material.
The solvent is introduced near the bottom of the column and it flow upward counter currently to the solids. A pump supplies the solvent and flow rate is monitored by means of a Rotameter. Solvent feed tank is kept in a bath fitted with heater. A digital temperature controller is used to control and measure the temperature of feed
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
The setup is designed to demonstrate principles of extraction in a Bonnotto type extraction column. It consists of a SS column, feed tank with heating arrangement, receiving tanks and piping. Rotameter is provided for flow measurement.
The column is divided into multiple stages; each stage consists of a plate and a mechanical agitation section. The circular plates are arranged one above the other in opposite radial opening, yield higher extraction efficiency than conventional packed column.
The solids are introduced at the top through a hopper spread over the top plate and pushed to slot to fall to the next plate below and so on to the bottom of the column. The solvent is introduced near the bottom of the column and it flow upward counter-currently to the solids. A pump supplies the solvent and flow rate is monitored by means of a Rotameter. At the bottom of column a screw conveyor arrangement is done to remove the extracted solids driven by means of an electric motor. Solvent feed tank is kept in a bath fitted with heater. A digital temperature controller is used to control and measure the temperature of feed
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
The setup is designed to demonstrate principles of liquid-liquid extraction and mass transfer operation in a packed column.
The set up consists of a glass column, packing, feed tanks, air regulator with pressure gauge, receiving tanks and piping. Rotameter are provided for flow measurement
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
The set up consists of glass column, feed tank, CO2 cylinder with regulator, air regulator with pressure gauge, Rotameter, receiving tray and piping. Metered quantity of fluid is distributed along with the walls of column from the top while metered gas and airflow is passed through the bed vertically upwards.
The gas air mixture is absorbed in the liquid. All the flow rates can be independently varied to simulate different conditions and by measuring the concentration of gas absorbed in the liquid the overall volumetric mass transfer coefficients can be calculated.
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
The set up consists of glass column, packing material, air rotameter and piping. Metered quantity of airflow is passed through the packed bed vertically upwards.
The flow rate can be independently varied to simulate different conditions using rotameter. Naphthalene balls of known weight and diameter are used to form the packed bed for the calculation of mass transfer co-efficient of vaporization in air
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
The setup contains all necessary accessories to determine the diffusion coefficient of components in the liquid phase.
The discussion cell is a well designed one to avoid any error during equimolal counter current diffusion between liquids of different concentration on each side of the cell. The diffusion vessel is of high quality Borosilicate Glass with a porous cell made up of ceramic. The Concentration of Solution is precisely measured with a precision Conductivity meter provided along with the setup.
The vessel is mounted over a Magnetic Stirrer cum hot plate of Superior quality provided with controls for vary the temperature and RPM to calculate the rate of diffusion at different temperature and mixing level
Experiments
Features
Utilities Required
Price on Request: Get Latest Price
The set-up is designed to demonstrate and stimulate the phenomena of crystallization. Swenson Walker crystallizer is a continuous type crystallizer. This operation involves both heat and mass transfer. Crystallization is the formation of solid particles within a homogeneous phase. Its wide use has a two-fold basis; a crystal formed from an impure solution is itself pure.
The setup consists of a top open jacketed round bottom trough. A ribbon mixer is provided in crystallizer trough, which rotates at low rpm for agitation of saturated solution. The saturated solution is prepared in a tank fitted with heater and a stirrer. This hot saturated solution is fed at one end of the crystallizer and flows slowly towards the other end while being cooled and is allowed to flow back in hot feed tank making the process continuous. The crystals sediments at the bottom of the trough, and can be washed out at the end of process. Arrangement for Cooling water circulation and flow measurement in jacket is made by using storage type water tank, a pump and a rotameter. Necessary instrumentation is done for temp measurement
Experiments
Features
Utilities Required